The dark standing-seam metal roof and mansard walls of a house, above light rendered walls with a cornice

Wind barrier installation: how to fit a breather membrane

Published

A wind barrier, or breather membrane, is a vapour-open sheet fixed outside the insulation, behind the cladding or under the roof covering: it keeps wind and rain out and lets moisture from the wall escape. It usually goes on printed side out, in horizontal runs from the bottom up, with taped joints and an air gap behind the cladding.

Wind barrier vs vapour barrier: what each layer does

A wind barrier protects the insulation from the outside and a vapour barrier from the inside, so one cannot replace the other. Wind blowing through mineral wool carries heat away; the membrane stops it and sheds rain that gets behind the cladding. For the wall to dry out, the inner layer has to be many times more vapour-tight than the outer one.

  • Wind barrier: outside the insulation; stops wind and water, lets vapour out; a low Sd value (vapour resistance in metres, on the label).
  • Vapour barrier: on the room side, behind the interior lining; stops moist indoor air; a high Sd value, or one that changes with the season for a vapour-control membrane.
  • Wind-tight boards, such as wood fibre: can replace the membrane where the system allows it and the joints are sealed.

Which side of the wind barrier faces out?

On most wind barriers the printed side, with the logo and text, faces out towards the cladding and the plain side faces the insulation. Some membranes are the same on both sides; others work one way round only and, reversed, may hold back less water or let less vapour out.

Go by the marking on the roll or the instructions, and check each wall before the counter-battens (timber strips fixed over the membrane) cover it.

How do you install a breather membrane on a wall?

Unroll the membrane horizontally from the bottom up, so each run overlaps the one below like roof tiles and rain flows over every lap. The counter-battens, fixed along each stud, then hold it and form the ventilated gap behind the cladding.

  • Overlap the runs, usually by 10 to 15 cm or as the instructions say; many rolls have a printed line for it.
  • Put end joints on a stud, so they can be taped against firm timber.
  • Pull the membrane flat but not tight, or it tears at the staples.
  • Fit the counter-battens soon: in an autumn gale a sheet held only by staples flaps and tears.
  • Leave the gap, usually a few centimetres deep, open at the bottom behind insect mesh and at the top, and keep the membrane off the cladding.
A workshop with OSB board on the walls and ceiling, metal shelving, a work lamp and a dust extraction hose above a panel saw

Renewing a facade or roof? We fit the wind barrier

Call us or send a few photos or a short description, and after a site visit we will prepare an estimate for the facade insulation or roof work, wind barrier included.

Discuss a projectCall +371 29 131 310Paving & exterior works

Taping the wind barrier: overlaps, windows, doors and pipes

A wind barrier stops wind only where its joints are closed, so laps, edges and openings are taped on a dry, clean membrane, with its self-adhesive edge strip or the tape the instructions specify. Many leaks start at windows: Latvian autumn rain is often wind-driven, and an open joint beside a frame lets it straight into the insulation.

  • Overlaps: along their full length where the instructions ask; end joints and corners always.
  • Windows and doors: fold the membrane into the reveal and tape it to the frame all round, the upper piece over the lower.
  • Pipes and cables: a purpose-made collar or short overlapping strips of tape.
  • Tape: one made for outdoor membranes, ideally from the same system; household tape comes loose in the cold and damp.

Wind barrier for a roof: the underlay beneath tiles or metal

On a pitched roof the underlay, usually a breathable membrane under the tiles or sheet metal, does this job. It catches rain and snow blown under the covering and condensation from metal, and drains the water to the eaves. A breathable membrane can lie on the rafters right over the insulation, while a less vapour-open underlay film, still sold as anti-condensation film, also needs a ventilated gap between the film and the insulation.

  • Lay the runs parallel to the eaves from the bottom up; low-pitched roofs often need a wider overlap.
  • Counter-battens along the rafters form the gap, and the roofing battens run across them.
  • At the eaves, take the membrane onto the eaves flashing or into the gutter.
  • At the ridge, let the air out, usually through a vented ridge.

How to order wind barrier installation: what we check and where to start

What Else fits wind barriers on walls and roofs in Riga and across Latvia as part of facade insulation, re-roofing or a turnkey house. We first look at the wall or roof on site, then agree the build-up, scope and estimate with you before work starts.

The first step is a call or a request with a few photos. Before the cladding goes on, we check the membrane for faults that are hard to fix later:

  • The plain side facing out on a membrane that works one way round.
  • Laps in the wrong order, or a ventilated gap that is missing or blocked.
  • Plastic vapour barrier film on the outside, trapping moisture in the wall.
  • Untaped tears and open joints at windows, doors and pipes.

FAQ

Do wind barrier overlaps need to be taped?
Usually yes: many instructions ask for laps taped or bonded along their full length, because loose laps let wind in between the sheets. End joints, corners and openings are always taped.
Can vapour barrier film be used as a wind barrier?
No. Outside the insulation, plastic vapour barrier film traps the moisture that should leave the wall, so the insulation and timber stay damp. Use a vapour-open wind barrier or a wind-tight board.
How long can a wind barrier stay uncovered?
As long as its instructions allow, often a few weeks to a few months, because sunlight weakens the membrane. Behind open-joint cladding, with gaps between the boards, use a membrane made for permanent exposure to daylight, and keep to its limits on joint width.
Can you fit a wind barrier on our house?
Yes, as part of facade insulation, re-roofing or a turnkey house, so the membrane, counter-battens and finish are planned as one job. Call us or send a request with photos; we then visit the site and prepare an estimate.

Start with a call or a few photos

Tell us about the job over the phone, or send photos or a short description, and we will agree on a time to see the site and prepare an estimate.

Discuss a projectCall +371 29 131 310